Click pictures

Ultra

BEP-Ultra



The BEP-Ultra is used with an Ultra BEP mat or an Ultra BEP Concentrator.

It requires and is connected to a BCX Ultra , which provides programs with sequences and frequencies, intensity control, and timers. With the BCX Ultra, custom programs can be created.

The BEP-Ultra can be used with a BCX Ultra with other BCX Ultra Accessories at the same time, with their frequencies and pulses synchronized.

The BEP-Ultra turns on and off automatically as BCX-Ultra programs are run.



Instructions for Operation

Specifications

Technical Resources: Answers to Questions you have


Instructions for Operation

The BEP-Ultra system consists of an BEP-Ultra Control Unit, an Ultra BEP Mat or Ultra BEP Concentrator, and a BCX Ultra

1. Plug the cord from the Ultra BEP Mat or the Ultra BEP Concentrator into the rear of the Control Unit

2. Plug the supplied cord from rear of the BCX Ultra into the rear of the BEP-Ultra Control unit

3. Power on the BCX Ultra and select a program

4. Select BEP, or BEP with another BCX Ultra Accessory

5. Run a BCX Ultra Program

6. Press "Pause" to Pause or Continue

7. Autoshutoff at the end of the program, if selected


Specifications

Model: BEP-Ultra
Type
Continuous Low Power Magnetic Wave Device
Application
Connects to BCX Ultra Auxiliary connector through a cord
Powered by BCX Ultra
Configuration

Balanced, Floating
Energy type

Magnetic Waves
Frequency Modes of Operation
Single or Mixed Frequencies with or without Variable Frequency Carrier
Linear and Square Frequencies and Carrier
Waveform Type Squarewave, Sinewave, Square Sweep, Trapezoid, Triangle, Hoyland, Linear Ramp Up, Linear Ramp Down, Exponential Ramp Up, Exponential Ramp Down, Equal Odd Order Harmonics, Equal Even Order Harmonics, Custom 1, Custom 2, Custom 3
Range 1 to 10,000 Hz

Resolution 1.00000 to 9.99999 Hz (0.00001 Hz)
10.0000 to 99.9999 Hz (0.0001 Hz)
100.000 to 999.999 Hz (0.001 Hz)
1,000.00 to 9,999.99 Hz (0.01 Hz) and 10,000 Hz
Maximum
Simultaneous
Frequencies
2 Individual
6 Equal Intensity Harmonic Multipliers
Multiple with Pulse and Frequency Harmonics
Multiple with Custom Arbitrary Waveforms
Duty Cycle,
Modulation
& Gate
Modes of Operation Variable Duty Cycle 1 to 100%
Single or Multiple Frequencies
Square or Linear Drive Frequencies
Waveform Types Squarewave, Sinewave, Square Sweep, Trapezoid, Triangle, Hoyland, Linear Ramp Up, Linear Ramp Down, Exponential Ramp Up, Exponential Ramp Down, Equal Odd Order Harmonics, Equal Even Order Harmonics, Custom 1, Custom 2, Custom 3
Range 1 to 10,000 Hz

Resolution 1.0000 to 9.9999 Hz (0.0001 Hz)
10.000 to 99.999 Hz (0.001 Hz)
100.00 to 999.99 Hz (0.01 Hz)
1,000.0 to 9,999.9 Hz (0.1 Hz) and 10,000 Hz
Maximum
Simultaneous
Modulation
Frequencies
1 Individual
2 Equal Intensity Harmonic Multipliers
Multiple with Pulse and Frequency Harmonics
Multiple with Custom Arbitrary Waveforms
Programs 1236 Internal non-volatile (User re-nameable)
255 User non-volatile (Completely configurable including name)
Sequences 80 Sequences per Program Single direct
40 Sequences per Program Mixed or Carrier direct
Sweep
Sweep Frequencies with Upper and Lower limits
Set Dwell and Direction Up, Down, or Wobble
Chain
Chain up to 100 Programs
Repeat Programs for unlimited run time
Intensity
1 to 100%
Timer
1 to 120 Minutes
Shutoff
Auto Shutoff or Manual
Power Output
20 Watts Max.
Mat Gauss: 4.7, Mat Area: 15-1/2 Square Feet
Concentrator Gauss: 18, Concentrator Area: 7 Square Inches


BCX Ultra Products and accessories are sold
through Distributors Internationally.


Copyright 2019